    This integration equips multiple cameras with switching capabilities based on these camera zones, improving the room’s overall camera coverage and the experience for remote participants. Camera zones are set up using the Nureva App or Nureva Console cloud. This article focuses on setting up the integration using the Nureva App.

    Step 1: Placement, connections and network access


    System placement

    For the HDL410 system to provide the most accurate sound location data, Nureva recommends the microphone and speaker bars be installed on opposite or perpendicular walls. This positioning produces accurate X and Y data.

    Recommended installation positions are shown in the diagrams below.

    good_position_1(1)
    good_position_2(1)
    good_position_3(1)
    bad_position_1(1)
    bad_position_2(1)
    bad_position_3(1)

    Hardware connections

    Connect the HDL410 and CAM230 as shown in the connection diagram below.

    Learn more about connecting HDL410 system components

    connection_diagram_CAM230_04.24

    Network access

    Data is exchanged between the HDL410 connect module and the CAM230 to facilitate camera switching. The connect module and CAM230 must be connected to the same network for the data exchange to happen.

    INOGENI recommends reserving an IP address on the network for the CAM230. Using the reserved IP address will help with the initial setup and maintain communication between the CAM230 and the HDL410 connect module.

    Explore reserving an IP address

    Step 2: Update CAM230 firmware

    Important: The CAM230 must use firmware version 2.2 or later for this integration.


    INOGENI offers a web portal for the configuration and management of the CAM230. The firmware is updated using this web portal and a downloaded file.

    The CAM230 and computer must be on the same web portal network to make a connection. An alternative option is to connect the computer directly to the CAM230. If the web portal or computer does not recognize the CAM230, try the following:

    • Ensure the CAM230 is assigned to a reserved IP address on the network.

    • Confirm the computer and CAM230 are connected to the same network.

    • Power cycle the CAM230.

    • Check the Ethernet cable connections.

    • Try different Ethernet cables.

    • Check the USB cable connection between the computer and CAM230.

    Logging in to the CAM230 web portal

    1. Access the web portal by entering the IP address 169.254.10.10 into a browser.

    2. Complete the login with username admin and password admin.

    3. The portal will open showing the Status tab.

      • The information shown under General includes the firmware version and the CAM230 IP address.

    4. Check the firmware version in the Status tab.

    5. If the firmware is earlier than version 2.2, go to the CAM230 resources webpage.

      • Go to the Firmware section at the top of the page.

      • Click the most recent firmware release.

      • A zip file will download containing the WIC file and release notes.

      • Extract the zip file.

    cam230_portal_status_tab_04.24

    Installing the firmware update

    1. From the CAM230 web portal, select the System tab.

    2. Scroll to the Update section at the bottom of the portal.

    3. Press the Choose File button and select the extracted WIC file.

    4. Click the Update CAM230 button to begin the update.

      • The firmware update will take up to 1 minute to complete.

      • After the update, the CAM230 will restart and the portal will refresh.

    Important: The CAM230 and the computer must be connected to the same network.

    Step 3: Obtain a REST API access token

    A REST API access token is needed in Step 5 of setting up this integration. This token is generated in the CAM230 web portal. If a token has already been created, the existing token can be looked up.

    Generate a new REST API access token

    1. Select the System tab.

    2. Go to the Security section at the top of the page.

    3. Press the Generate REST API access token button to generate the token.

    Important: Keep the web portal open to copy and paste the token during Step 5. If a new REST API token is generated, update Nureva Console with the new token.

    generate_token_cam230_04.24

    Look up existing REST API access token

    1. Select the System tab.

    2. Go to the Security section at the top of the page.

    3. Press the Get current REST API access token button.

    4. A new web page will open and show the REST API access token.

      • Copy the token from this page.

    5. Press the back button on the browser to return to the CAM230 web portal.

    Step 4: Connect to the Nureva App and update HDL410 firmware


    Connect to the Nureva App

    The HDL410 system must be connected to the Nureva App before setting up camera switching.

    1. Open a browser and enter the device's  IP address into the search bar.

    2. When prompted for a password, enter the HDL410 enrollment code and click Continue.

    3. The app will advance to the device management page.

    Get started with the Nureva app

    Updating the HDL410 firmware

    To ensure optimum audio quality and access to the latest features, the HDL410 firmware must be current. An update button will be available in the Nureva app if a firmware update is required. Advance to the next step once the HDL410 firmware is up to date.

    Step 5: Enable camera switching integration

    Note: INOGENI recommends reserving an IP address on the network for the CAM230. Using the reserved IP address will help with the initial setup and maintain communication between the CAM230 and the HDL410 connect module.

    1. From the Home page dashboard, open Integrations.

    2. Choose Camera switching and enable it by moving the toggle to the right.

    3. Enter the IP address or the hostname.

    4. Enter the Port number (Port 443 is the default and will apply to most integrations).

    5. Copy and paste the REST API access token that was generated in Step 3.

    6. Press the ‘Connect’ button to connect to the CAM230.

    app_camera_switching_controls_05.24

    After the connection is complete, open the Coverage map. If the CAM230 integration has successfully been set up, camera switching controls will be available.

    If the camera switching controls are unavailable, check that the IP address and REST API access token have been entered correctly. Also, confirm that the HDL410 and CAM230 are switched on and connected to the same network.

    Step 6: Confirm placement

    The HDL410 system generates a coverage map showing the system's placement. The blue circles on the coverage map indicate where sound location data is being generated within the room. The system placement must be shown accurately on the coverage map to ensure accurate camera switching.

    Confirm system placement

    The coverage map should show the positioning of the microphone and speaker bars as they are in the room. If the coverage map placement and the actual placement do not match, the system should be recalibrated.

    coverage_map_bar_placement_05.24

    The following steps are taken to perform recalibration through the Nureva app. Make sure there are no audible sound sources in the room other than normal ambient noise (e.g., no music playing, no people talking).

    1. From the Home page, open Settings.

    2. Select Audio processing.

    3. Choose Recalibrate and then Start.

    When the calibration signal stops and the indicator lights return to a normal state, the recalibration is complete. The HDL410 system placement on the coverage map should now represent the actual placement in the room.

    Learn more about system calibration

    Step 7: Create coverage map zones

    A zone defines an approximate area within a room. The data to map each zone, as well as the indication of when a sound is detected within each zone, is sent to the CAM230 to facilitate camera switching.

    Creating a zone

    1. Press Create zone from the side menu on the coverage map page.

    2. A zone will appear at the center of the coverage map.

    3. Drag the zone within the coverage map to the required location in the room.

    4. Adjust the zone to the required size using the drag handles.

    5. Press Apply to save the zone.

    coverage_map_zone_drag_05.24

    Editing the zone name

    Edit the zone name by selecting the “T” from the editing bar above the zone. Naming the zone to associate it with the camera’s input and coverage can make it easier to configure camera switching. For example, if Camera 1 is focused on the audience, use Audience for the zone name.

    Deleting a zone

    Zones can be deleted by choosing the zone from the coverage map and then selecting the trash can icon from the editing bar above the zone.

    Testing zones

    Zones can be tested by speaking in each zone area within the room. It is recommended the tester talk for at least one minute while moving to all the edges of the zone being defined. As sound location data is captured and displayed on the coverage map, it will help confirm the zone position and size. The sound location data refreshes every minute.

    Adjust the zone size and position if required. All sound data above 45 dB will be shown on the coverage map but only data above 60 dB for a specified length of time will be used to initiate a camera switch. A zone cannot be applied if:

    • It’s overlapping with another zone.

    • It doesn’t have a name.

    • It has a name that’s being used for another zone.

    • Its name exceeds 50 characters.

    Step 8: Configure camera switching settings


    Assigning cameras to zones

    • Select a zone to view the zone tools. Choose the camera icon to open a menu of connected cameras. Assign the desired camera to the zone and Apply.

    Default Camera

    • Open Camera switching on the coverage map to define the Default camera. Select a camera from the Default camera menu. This is the camera that the CAM230 switches to whenever voices are not detected.

    camera_switching_nureva_app_06.07.24

    In this example, Camera 1 is associated with the presenter and Camera 2 is with the audience.

    Adjust camera switching trigger timing

    The INOGENI CAM230 activates camera switching when it detects sound in a specific zone for at least 1 second. If no sound is detected, it switches to the default camera. The default time for triggering the switch is 1 second and can be adjusted to match the room’s needs.

    To adjust the timing of the camera switching open Camera switching.

    • The minimum sound duration to trigger a camera switch.

    • The maximum time to wait before switching to the default camera.

    Turning off automatic switching

    To turn off automatic camera switching, press the input button on the CAM230 for the corresponding camera. Automatic camera switching can be resumed by pressing the same input button.

    cam230_front_manual_switching_controls_04.24

    Automatic camera switching can turned on and off during a conference call. When the conference is over, the CAM230 will return to automatic switching.

    CAM230 status lights

    The CAM230 has status lights on the front of the device. These lights help determine the status of the device and can be used to help troubleshoot.

    cam230_front_status_lights_04.24

    Power input (PWR)

    Power over Ethernet (PoE)

    Input lights (1, 2, 3)

    • Off — no power

    • Solid — device has power

    • Off — no power from PoE

    • Solid — device has power from PoE

    • Off — Camera not detected

    • Dim — Camera detected but not selected

    • Bright — Camera selected

    • Blinking — Returned to automatic switching

    Troubleshooting


    HDL410 system

    General issues

    1. Ensure the firmware is up to date.

    2. Power cycle the connect module.

    3. Check the cables between the connect module and the microphone and speaker bars.

    4. Check the USB cable between the computer and connect module.

    Coverage map and zones

    1. Confirm the HDL410 system is placed as shown in Step 1.

    2. Ensure the HDL410 is the default audio device for the operating system.

    CAM230 camera selector

    General issues

    1. Power cycle the CAM230.

    2. Check the Ethernet cables.

    3. Check the USB cable.

    Device detection issues

    1. Confirm the firmware is version 2.2 or later.

    2. Ensure the CAM230 is assigned to a reserved IP address on the network.

    3. Confirm the computer and CAM230 are connected to the same network.

      • An alternative option is to connect the computer directly to the CAM230.

    4. Ensure the cameras are on the same network.

    5. Check the cables and connections to the cameras.

    Tip: If configuring the integration during a videoconferencing call, it is recommended the call is ended and a new one is started before testing the setup.