Release notes — November 2026

Prev Next

Introduction

These release notes apply to the November 2026 software release for Nureva® HDX systems. This release introduces new capabilities and includes fixes and enhancements focused on improving system stability, usability and overall performance.

The release includes noise suppression, Auracast™ broadcast audio functionality, improvements to autocalibration and additional system updates.


Want to receive email notifications for new releases? Subscribe today.


What’s new with this release?

Noise suppression

This build introduces noise suppression to reduce static background noise such as HVAC and fans.

  • Noise suppression is enabled by default and cannot be modified.

  • Disabling third-party noise suppression is recommended, as using multiple noise-suppression filters can degrade audio quality.

Auracast broadcast audio

Auracast broadcast audio for assistive listening is now available for HDX systems.

  • Auracast broadcast audio is disabled by default and must be enabled to use it.

  • A single broadcast channel is supported.

  • Optional privacy is ensured by enabling encryption or a passcode.

  • Inputs are preconfigured to HDX microphones, USB and aux-in and cannot be modified.

  • Options included for 16, 24 or 48 kHz broadcast quality.

    • We recommend 24 kHz for the best compatibility.

Autocalibration

On power-up, the HDX system will automatically run a calibration if the number of audio bars or microphone pods has changed since the last calibration.

Known issues

Intermittent calibration audio issue

  • In rare instances, the calibration process may produce a continuous buzzing sound.

    • If this occurs, restarting the HDX system resolves the issue.

Occasional echo cancellation performance issues

  • Some environments may experience intermittent echo cancellation performance issues during calls.

Coverage map refresh after relocating hardware

  • If HDX audio bars are moved after setup, the coverage map may not update their locations immediately after recalibration.

    • Restarting the system refreshes the shown locations.

Brief red status indicator light after calibration

  • You may notice a brief red status indicator light on the audio bar and microphone pod immediately after calibration completes.

    • It does not affect system operation and will clear automatically.

What to expect

  • The update will be deployed on November 23, 2026.

  • If your HDX system is already connected to Nureva services it will automatically update. Otherwise you will need to update the system manually in the Nureva App.

Note: The update process may temporarily interrupt system availability while the firmware is installed and the device restarts.

Release information

Nureva App

Android™ version: 1.68.0

iOS and iPadOS® version: 1.68.0

Nureva App for Windows® version: 1.68.0.416891

HDX systems

HDX systems: 0.2.1780351316


The Auracast™ word mark and logos are trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Nureva Inc. is under license. Other trademarks and trade names are those of their respective owners.