Is the HDL300 compatible with the Lifesize® Icon 600™?

Yes, the HDL300 works with the Lifesize Icon 600 conference room solution.

To get started, first check that the HDL300 is up-to-date and set up correctly:

  1. Connect the PoE cable (provided) to the RJ45-1 port on the connect module to the rear port on the HDL300 system
  2. Plug in the 54VDC power supply and connect a laptop to the connect module using the USB-A to USB-B cable (provided)
  3. Download and run Nureva Room Manager
  4. In Nureva Room Manager, under 
    1. Product updates => Check for firmware updates
    2. Audio conferencing system
      1. Controls
        1. Microphones => set the mic level to 80%
        2. Speakers => set the volume level to 100%
        3. Auxiliary ports
          1. Aux out => Microphone out (Mic level)
          2. Sleep mode => Disable
  5. Disconnect the connect module from your laptop and remove the USB cable.


Creating custom cables

Prepare two 3.5 mm jack cables with the three pins positive (+), negative (–) and ground (G) per Nureva auxiliary port recommendations. Label one Cable 1 and the other Cable 2.

See the article What kind of auxiliary jacks are compatible with the HDL300 system? for more information.


On the HDL300 connect module

  1. Plug Cable 1 into the Aux out port
  2. Plug Cable 2 into the Aux in port
  3. Connect the PoE cable (provided) to the RJ45-1 port on the connect module to the rear RJ45 port on the HDL300 system
  4. Plug in the 54VDC power supply


On the Lifesize Icon 600 CODEC

  1. Plug Cable 1 into Microphone in on the I/O panel
  2. Plug Cable 2 into the Speaker out on the I/O panel
  3. Connect the Lifesize Icon 600 video system to the network via the LAN port
  4. Navigate to the IP address of your Icon 600 video system portal from the web browser
    • Navigate Account Settings => Preferences => Audio
    • Set Audio Device to Echo Cancelling Speakerphone (HDL300)
    • Disable Acoustic Echo Canceller for Microphone in (if active)
    • Save all changes and Exit


To start a video conferencing call, see the article
 
Does the HDL300 system work with audio conferencing (UC&C) software? for more information on setting up and using the LifeSize UC&C client.

Connection Diagram

NOTE: The Nureva Aux In / Out connections are single-ended, unbalanced signals with default maximum output signals as given in the table below. Any equipment requiring voltages below these levels may result in clipping, distortion and, in extreme cases, damage to connected systems. Equipment requiring voltages above these levels will not be adequately driven by the HDL300 system’s output signal and may result in quiet / no audio on the channel. Before connecting to the Nureva Connect Module, make sure the third-party device voltage levels are adequate or adjusted properly by additional interfacing hardware.