--- title: "How to power cycle the HDL410 audio system | Nureva support" slug: "power-cycle-hdl410-system" description: "Learn how to power cycle your HDL410 audio system and troubleshoot overheating. " tags: ["Guide", "HDL410 system", "Nureva audio", "Meeting room audio", "Troubleshooting"] updated: 2024-04-12T15:49:58Z published: 2024-04-12T15:49:58Z canonical: "support.nureva.com/power-cycle-hdl410-system" --- > ## Documentation Index > Fetch the complete documentation index at: https://support.nureva.com/llms.txt > Use this file to discover all available pages before exploring further. # How to power cycle the HDL410 system Power cycling a Nureva® audio system is a great first step in troubleshooting. To complete a power cycle, follow the steps below. ## Power cycle the microphone and speaker bars Unplug the Ethernet cables from both RJ45 ports on the back of the connect module and then plug them back in. ![Connect module rear view - RJ45 jacks](https://cdn.document360.io/1ff82979-b9bd-4d03-9c0e-683bae60b79a/Images/Documentation/cm2.back.rj45ports_04.24.jpg) ## Power cycle the whole system Unplug the AC power adapter cable from the port on the back of the connect module. Wait about 10 seconds before plugging it back in. ![Connect module rear view - AC power adaptor](https://cdn.document360.io/1ff82979-b9bd-4d03-9c0e-683bae60b79a/Images/Documentation/cm2.power.port_04.24.jpg) ## Overheating warning | Indicator | Description | | --- | --- | | ![Solid red status indicator lights on connect module](https://cdn.document360.io/1ff82979-b9bd-4d03-9c0e-683bae60b79a/Images/Documentation/Copy%20of%20cm2.front.status.lights.explained.overheating_04.24.jpg) | **Solid red:** The connect module has overheated and needs to be shut down. - Unplug the connect module, wait a minimum of 10 minutes and then plug it in again. - If this issue persists, please [contact Nureva support.](https://www.nureva.com/contact-us/support) | ## Power cycle the connect module Unplug the AC power adapter cable from the port on the back of the connect module. Wait a minimum of 10 minutes before plugging it back in. ## Prevent overheating - Do not block the vents on the top, bottom or back of the connect module. - Ensure adequate space between all vents and other objects (a minimum of 2" or 5 cm) to promote airflow and cooling and to keep the circuits from overheating. - Avoid locations where ambient air reaches temperatures greater than 40° C. - Avoid installing the connect module in a confined space. - Avoid rack mounting the device. - Avoid installing the connect module close to other devices that generate heat. ![Connect module overheating warning](https://cdn.document360.io/1ff82979-b9bd-4d03-9c0e-683bae60b79a/Images/Documentation/cm2_vent_locations_04.24.png) The connect module requires a minimum of 2" (5 cm) clearance for airflow around the vents to avoid overheating.