Popular topics: Downloads HDL300 installation guide and requirements ► WM210i and WM307i installation guides and drawings Download Room Manager WM408i installation guide and drawings ► Other downloads WM210i and WM307i technical requirements Span Workspace Enabling QuickShare on your canvas ► Room Manager features overview Projector user manual Image brightness and color correction Creating your own template ► Specification sheet Hardware and tools checklist Sharing your canvas ► Using ready-to-use templates Adding a bookmark to your mobile home screen ► Installation best practices for the WM210i and WM307i systems Importing an image

Using the auxiliary ports

The auxiliary port options are located in the controls section of Nureva Room Manager.

All connections are unbalanced 3.5mm ports with a 3-contact tip ring sleeve.


Auxiliary out

Different auxiliary output modes can be selected in Nureva Room Manager for interoperability with different audio systems.

This table outlines different settings for the auxiliary out port for which type of device that's being connected. The default signal is echo-canceled microphone pickup with a maximum output level of 0.92 Vrms

Make sure to disable sleep mode before enabling any of the auxiliary out settings.


Microphone out (mic level)



The output contains in-room microphone pickup that is echo cancelled (near-end or local audio).

Microphone out (line level)



The output contains in-room microphone pickup that is echo cancelled (near-end or local audio).

Speaker out



The output contains far-end audio for playback on external speakers. The output is a mono signal and the HDL300 speakers are disabled. Near-end audio to the computer and far-end audio from the computer is sent by USB. For best results, volume should be controlled from the computer and amplifier settings should be fixed.

Mixed



The output contains both near-end and far-end audio mixed into one signal. With a mixed signal, hearing aid transmitters can transmit both the in-room audio and far end to hearing aid devices.




Mic level is maximum 0.23 Vrms (0.65 Vp-p) into 10 Kohm load.


Line level is maximum 0.92 Vrms (2.6 Vp-p) into 10 Kohm load.


Auxiliary in

Speaker input



Audio for playback to the room.  The signals from the auxiliary in port will get mixed with any signals from a USB audio source.
*make sure to disable sleep when using the auxiliary in.


Sleep

If you're using any auxiliary in or out connection, make sure to disable sleep under the auxiliary ports options. 